Mitsubishi Ecodan Review.

The Mitsubishi Ecodan R290 range runs from 5.2 to 11.5 kW on Mitsubishi Electric's own UK sheets, with a SCOP of 4.35 to 4.71 at a 35C flow and a flow temperature up to 75C. Its stated sound power, 54 to 58 dB(A), is higher than Vaillant's 48 to 51, and its longest warranty, 7 years, depends on who fits it.

Takes about two minutes. Installers pay us, so it is free for you.

Ecodan R290 range
5.2 to 11.5 kWat -7C air and 35C flow
SCOP at 35C flow
4.35 to 4.71R290 range, Mitsubishi Electric sheets
Sound power
54 to 58 dB(A)R290 range; 40 dBA at 1 metre
Warranty
3, 5 or 7 yearsby installer status, yearly service needed

Source: Mitsubishi Electric UK, Ecodan R290 product information sheets, editions effective January and April 2025; Mitsubishi Electric UK, Ecodan installer warranty terms and conditions (02.2026); all read 24 November 2026.

Updated · By Simon Doyle

In short

  • The current Ecodan R290 units run from 5.2 to 11.5 kW, with SCOP of 4.35 to 4.71 at a 35C flow and 3.38 to 3.51 at 55C.
  • Stated sound power is 54 to 58 dB(A), against 48 to 51 for Vaillant's aroTHERM plus on its own sheets. See the comparison.
  • Warranty is 3, 5 or 7 years depending on the installer's status, and it needs registration within 3 months and a yearly service.
  • Mitsubishi Electric does not publish a price on the sheets we read. The Energy Saving Trust puts a typical air source heat pump at about £12,000.
  • The £7,500 Boiler Upgrade Scheme grant is available in England and Wales through an MCS-certified installer.
On this page (11)
  1. What it is
  2. R290 range
  3. R32 range
  4. Cylinders
  5. Warranty
  6. How it compares
  7. Where it goes
  8. The bottom line
  9. Pros and cons
  10. Comparing quotes
  11. FAQs

What the Mitsubishi Ecodan Is

Ecodan is Mitsubishi Electric's range of air source heat pumps for homes. The units in the sheets we read are monoblocs: one outdoor unit that takes heat from the air, with insulated pipes carrying hot water into the house to a hot water cylinder and your heating system. There are two ranges, R290 and R32, named for the refrigerant each uses.

The April 2025 sheet for the larger R290 units says they are manufactured in the UK.

Source: Mitsubishi Electric UK, Ecodan R290 product information sheets, effective January and April 2025, read 24 November 2026.

Two black lagged pipes rising from the base of a heat pump unit and passing through a sealed hole in a red brick wall
The pipes from the outdoor unit carry hot water through the wall to the cylinder inside.

Switchable is independent of Mitsubishi Electric and is not paid by it for this review. We compare and introduce; we do not fit heat pumps. We take figures from the maker's own UK documents. How we review.

Ecodan R290 Range and Specs

The R290 units use a propane refrigerant with a global warming potential of 3, according to the sheets. Mitsubishi Electric lists a flow temperature of up to 75C for all six sizes below, and on the April 2025 sheet an A+++ class at 35C and A++ at 55C. Output is measured at an outdoor air temperature of -7C with 35C water leaving the unit.

Mitsubishi Ecodan R290: Mitsubishi Electric's own figures
ModelOutput (kW)SCOP at 35C / 55CSound power dB(A) (pressure at 1m)Refrigerant charge
PUZ-WZ50VAA5.24.42 / 3.3856 (40)0.60 kg
PUZ-WZ60VAA6.24.39 / 3.4356 (40)0.60 kg
PUZ-WZ80VAA8.24.35 / 3.4558 (40)1.0 kg
PUZ-WZ85V/YAA8.54.47 / 3.5154 (40)0.60 kg
PUZ-WZ100V/YAA10.04.62 / 3.4855 (40)0.82 kg
PUZ-WZ120V/YAA11.54.71 / 3.5155 (40)0.82 kg

Source: Mitsubishi Electric UK, Ecodan R290 product information sheets, editions effective January 2025 (50, 60 and 80) and April 2025 (85, 100 and 120), read 24 November 2026. SCOP is the figure on the sheet. The V and Y suffixes are single-phase and three-phase versions.

Ecodan R32 Range

The R32 range goes higher in output, up to 14 kW. R32 is the refrigerant these units use. We could not read a maximum flow temperature on the R32 sheets, so we do not give one.

Mitsubishi Ecodan R32: Mitsubishi Electric's own figures
ModelOutput (kW)SCOP at 35C / 55CSound power dB(A) (pressure at 1m)Refrigerant charge
PUZ-WM50VHA5.04.62 / 3.2461 (52)2.0 kg
PUZ-WM60VAA6.04.81 / 3.5758 (45)2.2 kg
PUZ-WM85VAA8.54.84 / 3.4858 (45)2.2 kg
PUZ-WM112VAA11.24.74 / 3.3460 (45)3.0 kg
PUZ-HWM140VHA144.33 / 3.2667 (53)3.3 kg

Source: Mitsubishi Electric UK, outdoor unit product information sheets, read 24 November 2026. Edition dates were not checked on these sheets, so confirm the model is still current with your installer.

The R32 sheets show higher sound pressure than the R290 ones, 45 to 53 dBA at 1 metre against 40. If you are choosing between the two ranges for a size, ask your installer for both sheets.

Ecodan Cylinders

The outdoor unit heats water, and a hot water cylinder stores it for taps and showers. Mitsubishi Electric's standard cylinders come in six sizes, 150, 170, 210 (small and large versions), 250 and 300 litres, and there are slimline 150 and 170 litre versions for tight spaces. The R290 packaged range includes a 200 litre cylinder.

A cylinder needs space, and homes with a combi boiler often have none, so ask your installer where it would go.

Source: Mitsubishi Electric UK, outdoor unit product information sheets, read 24 November 2026.

A tall white hot water cylinder with copper and grey insulated pipework in an under-stairs cupboard
A cylinder in a cupboard under the stairs, the usual indoor half of the system.

Ecodan Warranty

Mitsubishi Electric's warranty on heat pumps under 20 kW depends on the installer's status with the company. Cylinders and ancillaries carry 3 years on every tier.

  • Standard account installer

    3 years on the heat pump.

    From commissioning, if registered.

  • Accredited Ecodan installer

    5 years, if the installer holds the status and meets the terms.

    Reverts to the standard terms if the installer loses the status.

  • Heating business solutions partner

    7 years, on the same conditions.

    The longest cover available.

Registration must be done within 3 months of commissioning, or cover is 12 months from delivery. The terms also require installation to follow the manual, annual servicing, and say that if the conditions are not met only the one-year standard warranty applies. The homeowner guarantee page also says a service is due every year to maintain the warranty. The warranty document does not mention MCS.

Source: Mitsubishi Electric UK, Ecodan installer warranty terms and conditions (02.2026), created 9 October 2026, and Mitsubishi Electric UK, homeowner guarantee, read 24 November 2026.

How the Ecodan Compares

We set the Ecodan R290 range against three rivals using each maker's own UK documents. A gap means we could not read that figure from the maker.

Ecodan R290 against three rivals
Ecodan R290Vaillant aroTHERM plusGrant Aerona 290Daikin Altherma 4 H
Sizes (kW)5.2 to 11.53.5 to 124 to 15.5Not read
SCOP at 35C4.35 to 4.714.36 to 5.034.56 to 5.08Class A+++ only
SCOP at 55C3.38 to 3.513.06 to 3.633.33 to 3.74Not read
Sound power dB(A)54 to 5848 to 51Not readNot comparable
Max flow75C75CNot readUp to 75C
Warranty3, 5 or 7 years by installer statusUp to 7 years (brochure)7 years with a Grant G1 installer2, 5 or 7 years by registration and installer

Source: Read 24 November 2026: Mitsubishi Electric UK, Ecodan R290 product information sheets; Vaillant aroTHERM plus tech sheet (December 2024), installer's quick guide (March 2024) and brochure (January 2026); Grant UK, Aerona 290; Daikin UK, Altherma 4 and warranty. Makers may test under different conditions.

On the stated figures the Ecodan sits in the middle on SCOP, with a higher sound power than Vaillant's sheets give. Our best air source heat pump page compares six ranges and explains how to choose.

Where an Ecodan Goes and Who It Suits

Like any air source heat pump, the Ecodan outdoor unit stands on a plinth or feet against a wall, with space around it. In England most units on homes can go up without a planning application under permitted development, with a noise calculation under MCS 020(a) and conditions for listed buildings. The heat pump also needs a hot water cylinder inside.

On the stated figures, an Ecodan R290 suits a home that needs a size between 5 and 11.5 kW, wants a flow temperature up to 75C for existing radiators, and will use an installer who holds one of Mitsubishi Electric's higher tiers for the longer warranty. It may be less suited to a unit placed close to a bedroom window, where a lower stated sound power might matter more.

Source: planning position as set out on our best air source heat pump page; Mitsubishi figures as above.

A heat pump on a concrete plinth in a snowy side passage beside a brick house with a clear gap to the wooden fence
A unit in a side passage with a clear gap to the fence. Placement affects both noise and access.

The Bottom Line

On Mitsubishi Electric's own UK sheets, the Ecodan R290 is a well-documented range from 5.2 to 11.5 kW with SCOP of 4.35 to 4.71 at a 35C flow and flow temperatures up to 75C. Its stated sound power is higher than Vaillant's, and its longest warranty depends on your installer's status and a yearly service.

It is worth a place on a shortlist alongside two or three rivals. Ask each installer for the same size, the model's datasheet, the warranty tier and the price after the £7,500 grant, and compare them line by line.

Compare heat pump quotes

Pros And Cons

Pros

  • Mitsubishi Electric publishes SCOP, sound power and output for each R290 size
  • SCOP of 4.35 to 4.71 at a 35C flow, with an A+++ class at 35C on the April 2025 sheet
  • Flow temperature up to 75C on the R290 range
  • Sizes from 5.0 kW to 14 kW across the R290 and R32 ranges, and cylinders from 150 to 300 litres
  • The larger R290 units are manufactured in the UK, says the April 2025 sheet

Cons

  • Stated sound power of 54 to 58 dB(A) on R290 and up to 67 on R32, against 48 to 51 on Vaillant's sheets
  • The 5 and 7 year warranties depend on the installer's status, registration within 3 months and a yearly service
  • SCOP at 55C of 3.38 to 3.51 on R290, below Grant's stated top of 3.74
  • Output is stated at -7C air, so it is not directly comparable with figures given at 7C
  • No maximum flow temperature on the R32 sheets we read

On this page

  1. What it is
  2. R290 range
  3. R32 range
  4. Cylinders
  5. Warranty
  6. How it compares
  7. Where it goes
  8. The bottom line
  9. Pros and cons
  10. Comparing quotes
  11. FAQs

How To Compare Quotes

Get at least three quotes and compare them line by line. Prices for the same job can differ a lot.

  • The installer is MCS certified. You need an MCS-certified installer to get a Boiler Upgrade Scheme grant, and the installer applies for it.
  • A heat loss survey first. The heat pump should be sized to your home, room by room, before you get a price.
  • What is in the price: the heat pump, hot water cylinder, any radiator upgrades, removing the old system, and the grant taken off.

How Switchable works

  1. Check. Tell us your postcode and a few details about your home. It takes about two minutes.
  2. Compare. Local installers who cover your area get in touch with quotes.
  3. Switch. Go ahead with the quote that suits you, or none at all. There is no obligation.

Switchable is free to use. Installers pay us for each introduction.

Mitsubishi Ecodan Review: Your Questions.

Still unsure?

0151 453 1765

Or email info@switchable.co.uk and we will get back to you.

Is the Mitsubishi Ecodan any good?

We do not score products. On Mitsubishi Electric's own sheets the Ecodan R290 range has SCOP of 4.35 to 4.71 at a 35C flow and flow temperatures up to 75C, with stated sound power of 54 to 58 dB(A). Compare it with rivals on the same size and warranty conditions.

How long does a Mitsubishi heat pump last?

We did not find a lifespan figure in the sources we read, so we do not give one. Mitsubishi Electric's warranty is 3, 5 or 7 years depending on the installer's status, with registration within 3 months and a yearly service.

How much does a Mitsubishi Ecodan cost?

The Mitsubishi Electric sheets we read give no price, because installers quote. The Energy Saving Trust puts a typical air source heat pump at about £12,000 installed, before the £7,500 Boiler Upgrade Scheme grant in England and Wales.

Is the Mitsubishi Ecodan noisy?

The R290 sheets give 54 to 58 dB(A) sound power and 40 dBA sound pressure at 1 metre. The R32 sheets give 58 to 67 sound power. How it sounds depends on where it sits, so ask the installer to place it away from bedroom windows.

What is the difference between the R32 and R290 Ecodan?

The refrigerant. The R290 units use propane with a global warming potential of 3, list a flow temperature of 75C and give 40 dBA at 1 metre, while the R32 sheets give 45 to 53 dBA at 1 metre and no maximum flow temperature that we could read.

Does the Ecodan qualify for the Boiler Upgrade Scheme?

The grant is £7,500 for an air source heat pump in England and Wales and needs an MCS-certified installer. Ask your installer to confirm the exact model qualifies before you accept the quote.

Where are Mitsubishi Ecodan heat pumps made?

The April 2025 Mitsubishi Electric sheet for the larger R290 units, 8.5 to 11.5 kW, says they are manufactured in the UK. We did not see a country on the other sheets.

Is a Mitsubishi or Daikin heat pump better?

The UK pages we read do not settle it. Mitsubishi publishes SCOP and sound power for its R290 sizes, while Daikin's Altherma 4 UK pages give an A+++ class and a flow temperature up to 75C but no SCOP. Our best air source heat pump page compares them.

Get Your Free Quotes Today.